Level 1: A Longer Fuse Wire: Does It Blow at a Lower Current?
Make the fuse wire twice as thick.
A fuse wire blows at 5 A. A wire of the same material but twice the diameter is fitted. Assuming heat is lost only through the surface, at a fixed rate per unit area at the melting point, it blows at about:
At the melting point, the heat produced per second equals the heat lost per second through the surface. The heat produced falls as 1/r² through the resistance, and the heat lost grows as r through the surface area.
So the thicker wire blows at about 2.83 × 5 ≈ 14 A, not 10 A. Doubling the diameter nearly triples the safe current, which is why a fuse's rating is set by the thickness of its wire.
Every Level 2 starts from a quick question, Level 1, and changes one thing. Seeing what that change does is the skill JEE Main tests. Try it here, free and with no signup, then read the worked answer.